Suntan New Products!

Suntan Technology Company Limited

---All Kinds of Capacitors

Fico feliz em informá-lo: Suntan lançou recentemente quatro tipos de novos produtos Triacs, bem-vindo para verificar nossa folha de dados conforme abaixo.

Se você estiver interessado em nossos produtos, por favor, envie sua pergunta para sales@capacitors.hk / info@capacitors.hk para obter mais informações!
 
Nova folha de dados TRIACS:
BT138-800E TRIACS
https://www.suntan.com.hk/pdf/Rectifier-Diode/BT138-800E.pdf
 
BTA16-800B QUATRO QUADRANT TRIACS
https://www.suntan.com.hk/pdf/Rectifier-Diode/BTA16-800B.pdf
 
BT134-600E SENSITIVE GATE TRIACS
https://www.suntan.com.hk/pdf/Rectifier-Diode/BT134-600E.pdf
 
BT139-800T TRÊS QUADRANT TRIACS
https://www.suntan.com.hk/pdf/Rectifier-Diode/BT139-800T.pdf

Su Suntan Chip Tantalum Capacitors - TS20L (Low ESR) Comes Back

Suntan Technology Company Limited

 ---All kinds of Capacitor
 
Привет всем
 
Вам нужны конденсаторы из танталового чипа в последнее время? Вот очень хорошие новости для вас!
Серия Suntan TS20L была снята с производства в течение очень долгого времени, однако, теперь мы объявляем, что можем снова предложить этот тип конденсаторов из тантала с низким показателем СОЭ!
Пожалуйста, проверьте нашу таблицу данных обновления, как показано ниже, мы также перечислим стандартный тип серии TS20 для вашей справки.
Вы можете свободно связаться с нами по адресу sales@suntan.com.hk / info@suntan.com.hk, чтобы проверить цену, спасибо.
 
Танталовый конденсатор чипа:

 

Suntan Modeling Absorptive Capacitors

Suntan Technology Company Limited
---All Kinds of Capacitors

Dielectric absorption in a capacitor is difficult to characterize accurately because of the very wide range of the time constants involved and because of the high level of performance required in the measuring equipment. To get a good characterization, the capacitor response must be measured for a range of frequencies at least three decades higher and lower than 1/τ0. Frequency domain measurements must be made with vector impedance analyzers that can accurately resolve a small resistive component in a largely reactive impedance (they must be able to accurately measure large values of Q). In the frequency domain the resistive portion of the impedance gives the most information about dielectric absorption. In the time domain, which is usually used for measurement longer than 100 ms, an ammeter is needed with very low bias current and the ability to resolve very low currents. If these instruments are available, then an accurate and complete model can be made, but such a model is often not required. To completely model dielectric absorption would require, in most cases, a range of accuracy that spans ten decades of frequency or more. Generally, however, the application does not warrant such a model and one can get by with a model that is faithful to the behavior of the physical component over a much smaller range of frequencies.

Page:[«]1[»]